西門子PLC主機CPU414H,SIMATIC S7-400H414-5H SYSTEM-BUNDLE系統H-1 X UR2-H,W / O內存卡,2個PS407 UC120/230V,10A,410M X同步模塊,2 X的SYNC-CABLE1M,2 X CPU 414-5H,4 X后備電池
============================================
*,質量保證,保修一年,提供技術服務,價格合理!
上海勵輝自動化科技有限公司(西門子自動化與驅動集團合作伙伴)
:馬 宇(銷售工程師) 直線:
手 機: (備注收件人)
以人為本,誠信為基,創新為魂,質量*,信譽*,
本公司**:西門子PLC S7-200 300 400 , 觸摸屏。變頻器,數控主板NCU系列,DP接頭現場總線,軟啟動器,工業以太網
============================================
訂貨號:6ES7414-5HM06-0AB0
產品功能 SIMATIC S7-400H 和 S7-400F/FH。
- 可應用在高可用性的 S7-400H 系統中
- 可與故障安全 S7-400F/FH 系統中 F 運行*與 F 兼容 CPU 一起使用。
- 帶有內置的 PROFIBUS DP 主站接口
- 帶兩個用于 Sync 模塊的插槽
CPU | |
6ES7 412-3HJ14-0AB0 | CPU 412-3H; 512KB程序內存/256KB數據內存 |
6ES7 414-4HM14-0AB0 | CPU 414-4H; 冗余熱備CPU 2.8 MB RAM |
6ES7 417-4HT14-0AB0 | CPU 417-4H; 冗余熱備CPU 30 MB RAM |
6ES7 400-0HR00-4AB0 | 412H 系統套件包括 2 個CPU、1個H型*機架、2個電源、2個1M 存儲卡、4個同步模塊、2根同步電纜,以及4個備用電池(PS407 10A) |
6ES7 400-0HR50-4AB0 | 412H 系統套件包括 2 個CPU、1個H型*機架、2個電源、2個1M 存儲卡、4個同步模塊、2根同步電纜,以及4個備用電池(PS405 10A) |
6ES7 412-1XJ05-0AB0 | CPU412-1,144KB程序內存/144KB數據內存 |
6ES7 412-2XJ05-0AB0 | CPU412-2,256KB程序內存/256KB數據內存 |
6ES7 414-2XK05-0AB0 | CPU414-2,512KB程序內存/512KB數據內存 |
6ES7 414-3XM05-0AB0 | CPU414-3,1.4M程序內存/1.4M數據內存 1個IF模板插槽 |
6ES7 414-3EM05-0AB0 | CPU414-3PN/DP 1.4M程序內存/1.4M數據內存 1個IF模板插槽 |
6ES7 416-2XN05-0AB0 | CPU416-2,2.8M程序內存/2.8M數據內存 |
6ES7 416-3XR05-0AB0 | CPU416-3,5.6M程序內存/5.6M數據內存 1個IF模板插槽 |
6ES7 416-3ER05-0AB0 | CPU416-3PN/DP 5.6M程序內存/5.6M數據內存 1個IF模板插槽 |
6ES7 416-2FN05-0AB0 | CPU416F-2,2.8M程序內存/2.8M數據內存 |
6ES7 416-3FR05-0AB0 | CPU416F-3PN/DP,5.6M程序內存/5.6M數據內存 |
6ES7 417-4XT05-0AB0 | CPU417-4,15M程序內存/15M數據內存 |
CPU 414–5H 是用于 SIMATIC S7-400H 和 S7-400 F/FH 的 CPU。它允許配置為一個容錯的 S7-400H 系統。它可與 F 運行*一起用于故障安全 S7-400®F/FH 自動化系統。內置的PROFIBUS-DP接口使它能夠作為主站或從站直接連接到PROFIBUS-DP現場總線。
Design
The CPU 414-4H features:
- A powerful processor:
The CPU achieves command runtimes as little as 45 ns per binary command. - 2.8 MB main memory (1.4 MB for programs, 1.4 MB for data);
load memory for user programs and configuration data for the S7-400H F/FH automation system; fast main memory for subroutines of the user program that are relevant to the process - A memory card:
For extending the integrated load memory. In addition to the program itself, the information contained in the load memory also includes configuration data for the S7-400H F/FH, which is why it takes up twice as much space in the memory. The result is that:- The integrated load memory is not sufficient for large programs, which is why the memory card is often required.
RAM and FEPROM cards are available (FEPROM for saving even when not connected to the power supply).
- The integrated load memory is not sufficient for large programs, which is why the memory card is often required.
- Easy removal:
Max. 65K digital and 4K analog inputs/outputs. - Multipoint-capable MPI interface:
The MPI enables the creation of a simple network with max. 32 nodes and a data transfer rate of 187.5 Kbit/s. The CPU can establish up to 64 connections to users of the communication bus (C bus) and the MPI.
Note:
If PROFIBUS DP and MPI interfaces are being used simultaneously, only the following bus connectors can be connected to the MPI interface:- With socket: 6ES7 972-0BB41-0XA0
- Without socket: 6ES7 972-0BA41-0XA0
- Mode selector:
Designed as a toggle switch. - Diagnostic buffer:
The last 120 alarm and interrupt events are stored in a ring buffer for the purpose of diagnosis. - Real-time clock:
Diagnostic reports from the CPU are provided with the date and time. - PROFIBUS DP interface:
The CPU 414-4H with PROFIBUS DP master interface enables distributed automation to be established at high speed and with easy operation. From the user's point of view, the distributed peripherals are treated like centralized peripherals (same configuration, addressing and programming).
Note:
If PROFIBUS DP and MPI interfaces are being used simultaneously, only the following bus connectors can be connected to the MPI interface:- With socket: 6ES7 972-0BB41-0XA0
- Without socket: 6ES7 972-0BA41-0XA0
Functions
- Block protection:
A password concept also protects the user program from unauthorized access as well as the keyswitch. - Integrated HMI services:
The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system. - Integrated communication functions:
- PG/OP communication
- Expanded communication (simple and high-availability)
Configurable Attributes
The STEP 7 "hardware configuration" tool and the installed S7-400H options package are used to configure the features and response of the S7-400H, including the CPUs, for example:
- Multipoint interface MPI:
- Definition of node addresses
- Startup/cycle behavior
- Stipulation of the maximum cycle time and communication load
- Address allocation:
Addressing of I/O modules - Retentive area:
Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories - Protection level:
Definition of access authorizations to program and data - System diagnostics:
Definition of the handling and scope of diagnostics messages - Timed interrupts:
Setting of periods - Configuration of H stations
Safety-related functions
The F-runtime license can be used to compile the failsafe F user program and run it on the CPU. A license is required for each S7-400F/FH system. 2 TÜV stickers are included.
Reporting functions
- Status and fault indicators:
LEDs indicate internal and external errors and operating modes such as RUN, STOP, Startup, "Master” mode, redundancy error, test function, etc. - Test functions:
The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components. - Information functions:
The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.
Technical Specifications
| 6ES7 414-5HM06-0AB0 |
CPU 414-5H PN/DP | |
產品型號 |
|
硬件產品型號 | 1 |
固件型號 | V6.0 |
一般信息 |
|
相關的編程軟件包 | STEP 7 V5.5 SP2,帶HF1 |
在 RUN 模式下 CiR 組態 |
|
CiR 同步時間,基本負載 | 100 ms |
CiR 同步時間,每個 I/O 從站的時間 | 0 µs |
供電電壓 |
|
24 V DC | ×; 通過系統電源供電 |
輸入電流 |
|
從背板總線 5 V DC,zui大 | 1.9 A |
從接口 5 V DC,zui大 | 90 mA;每個 DP 接口 |
功耗 |
|
功耗,典型值 | 7.5 W |
存儲器 |
|
工作存儲器 |
|
| 4 兆字節 |
| 2 兆字節 |
| 2 兆字節 |
| X |
裝載存儲器 |
|
| √ |
| 64 兆字節 |
| 512 KB |
| √ |
| 64 兆字節 |
后備 |
|
| √ |
| √;所有數據 |
| X |
CPU 塊 |
|
DB |
|
| 6000;范圍: 1 至 16000 |
| 64 KB |
FB |
|
| 3000;范圍: 0 至 7999 |
| 64 KB |
FC |
|
| 3000;范圍: 0 至 7999 |
| 64 KB |
OB |
|
| 64 KB |
嵌套深度 |
|
| 24 |
| 1 |
CPU 處理時間 |
|
位運算,zui小 | 18.75 ns |
字運算,zui小 | 18.75 ns |
定點數運算,zui小 | 18.75 ns |
浮點數運算,zui小 | 37.5 ns |
計數器、定時器及其保持性 |
|
S7 計數器 |
|
| 2 048 |
|
|
| √ |
| 0 |
| 2 047 |
| Z 0 至 Z 7 |
|
|
| 0 |
| 999 |
IEC 計數器 |
|
| √ |
| SFB |
S7 定時器 |
|
| 2 048 |
|
|
| √ |
| 0 |
| 2 047 |
| 無保持性定時器 |
|
|
| 10 ms |
| 9 990 s |
IEC 定時器 |
|
| √ |
| SFB |
數據區及其保持性 |
|
保持數據區域,總共 | 整個工作和裝載存儲器(通過后備電池) |
標志 |
|
| 8 KB |
| √ |
| MB 0 至 MB 15 |
| 8; 1 個存儲字節 |
局部數據 |
|
| 16 KB |
| 8 KB |
地址區 |
|
I/O 地址區 |
|
| 8 KB |
| 8 KB |
|
|
| 2 KB |
| 2 KB |
| 6 KB |
| 6 KB |
過程映像 |
|
| 8 KB |
| 8 KB |
| 256 字節 |
| 256 字節 |
| 244 字節 |
| √ |
子過程映像 |
|
| 15 |
數字量通道 |
|
| 65 536 |
| 65 536 |
| 65 536 |
| 65 536 |
模擬量通道 |
|
| 4 096 |
| 4 096 |
| 4 096 |
| 4 096 |
硬件組態 |
|
擴展設備,zui大 | 21 |
多CPU運行 | X |
接口模塊 |
|
| 6 |
| 6 |
| 4;只能是單模式 |
DP 主站數量 |
|
| 2 |
| 10 |
| X |
可運行的 FM 和 CP 的數量(*) |
|
| 參見自動化系統 S7-400H 故障容錯系統手冊 受插槽數和接口數的限制 |
| 參見自動化系統 S7-400H 故障容錯系統手冊 受插槽數和接口數的限制 |
| 14;其中zui多10個CP可作為DP主站 |
日時鐘 |
|
時鐘 |
|
| √ |
| √ |
| 1 ms |
| 1.7 ms;掉電 |
| 8.6 ms;上電 |
運行小時計數器 |
|
| 8 |
| 0 至 7 |
| 0 ~ 32767 小時 |
| 1 小時 |
| √ |
時鐘同步 |
|
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
第1個接口 |
|
接口類型 | 集成 |
物理 | RS 485 / PROFIBUS + MPI |
隔離 | √ |
接口供電(15-30V DC),zui大 | 150 mA |
連接源數量 | MPI: 32, DP: 32 |
功能性 |
|
| √ |
| √ |
| X |
MPI |
|
| 32 |
|
|
| √ |
| √ |
| X |
| X |
| √ |
| 12 Mbit/s |
DP 主站 |
|
| 16 |
|
|
| √ |
| X |
| X |
| √ |
| X |
| X |
| X |
| X |
| 12 Mbit/s |
| 32 |
|
|
| 2 KB |
| 2 KB |
|
|
| 244 字節 |
| 244 字節 |
| 244 字節 |
| 244 |
| 128 字節 |
第2個接口 |
|
接口類型 | 集成 |
物理 | RS 485 / PROFIBUS + MPI |
隔離 | √ |
接口供電(15-30V DC),zui大 | 150 mA |
連接源數量 | 16 |
功能性 |
|
| √ |
| X |
DP 主站 |
|
| 16 |
|
|
| √ |
| X |
| X |
| √ |
| X |
| X |
| X |
| X |
| 12 Mbit/s |
| 96 |
|
|
| 6 KB |
| 6 KB |
|
|
| 244 字節 |
| 244 字節 |
| 244 字節 |
| 244 |
| 128 字節 |
第3個接口 |
|
接口類型 | 可插入同步子模板(FO) |
插入式接口模塊 | 同步子模板 IF 960 6ES7 960-1AA04-0XA0 或 6ES7 960-1AB04-0XA0 |
第 4 接口 |
|
接口類型 | 可插入同步子模板(FO) |
插入式接口模塊 | 同步子模板 IF 960 6ES7 960-1AA04-0XA0 或 6ES7 960-1AB04-0XA0 |
通訊功能 |
|
PG/OP 通訊 | √ |
| 31 |
| 8 |
全局數據通訊 |
|
| X |
S7 基本通訊 |
|
| X |
S7 通訊 |
|
| √ |
| √ |
| √ |
| 64 KB |
| 462 字節;1 個變量 |
S5 兼容通訊 |
|
| √; (通過 CP zui多10個,以及 FC AG_SEND 和 FC AG_RECV) |
| 8 KB |
| 240 字節 |
| 24/24 |
標準通訊(FMS) |
|
| √;通過 CP 和可調用的 FB |
連接數量 |
|
| 32 |
S7 報文功能 |
|
報文功能所登錄站的數量,zui大 | 8 |
與符號相關的報文 | X |
與塊相關的報文 | √ |
同時激活的 Alarm-S 塊,zui多 | 100 |
Alarm 8 塊 | √ |
| 1 200 |
| 900 |
過程控制報文 | √ |
測試調試功能 |
|
狀態/控制 |
|
| √ |
| I/O、存儲器位、數據塊、分布式 I/O、定時器、計數器 |
| 70 |
強制 |
|
| √ |
| I/O,位存儲器,分布式 I/O |
| 256 |
狀態塊 | √ |
單步執行 | √ |
斷點數量 | 4 |
診斷緩沖 |
|
| √ |
| 3 200 |
| √ |
| 120 |
組態 |
|
組態軟件 |
|
| √;帶硬件更新,STEP 7 V5.3 SP2 以上 |
編程 |
|
|
|
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| √ |
| 8 |
專有技術保護 |
|
| √ |
尺寸和重量 |
|
所需插槽 | 2 |
尺寸 |
|
| 50 mm |
| 290 mm |
| 219 mm |
重量 |
|
| 995 g |