     First of all, thank you for buying one of our machines.
     
       We are producing Vibratory Finishing Machines, Vibration applied machines, Precision processing special machines with our accumulated technology and thorough quality systems under our motto that we serve our customers with the best quality products
    .
      We would like to introduce, through this manual, how to properly use the machine, to perform its best function in operation that our development and production team have made with their endeavors.
     
      This manual will guide the users to understand the equipment, how to use in the best conditions, how to increase productivity, how to maintain the equipment in the very simple way.
    For anything that is not sufficiently described, please feel free to contact our office, then we will supply with further information that we can do.
     
       We hope this equipment will do a good role in your business, Good luck!
     
                          From all the members of Jin Poong B.R. Tech.
     
     
    WARRANTY
     
    1.Warraty period of this equipment is 1 year or 2000 hours whichever comes first. and warranty period of the electrical parts is 6 months.
     
    韓國三星磨料  韓國三星磨料  韓國三星磨料  韓國三星磨料  韓國三星磨料
      This is based on the normal operation, operators mistake or mishandling of the equipment, excessive operation beyond its capability and failure to maintain on time will release the warranty obligation.
     
    2. In any case that the user has changed the machine parts or corrected without any prior agreement, this warranty will be invalid..
     
      PAINTING DURABILITY TESTER MACHINE
                  MODEL  :  TC - 15 (SM - 1502)
     
    I.  COMPOSITION OF THE EQUIPMENT
    1. VIBRATORY TUMBLER
    2. SOUND COVER
    3. AUTO WATER & COMPOUND SUPPLY SYSTEM
    4. CONTROL UNIT
       
    II.  SPECIFICATION OF THE EQUIPMENT
       1. VIBRATORY TUMBLER
       Tub interior dimension:  W180mm x L530mm
        In-put area dimension:  W130mm x L530mm
       LINING : Hot pour Polyurethane Casting, Thickness: 15mm
       Motor  : 220V x 1Hp x 3ph x 60Hz. (2 pole)
       Motor R.P.M : 3500
     2. SOUND COVER
       L920mm x W620mm x H900mm+120mm
       Top door with Gas Cylinder
     
    3. AUTO WATER & COMPOUND SUPPLY SYSTEM
       Water tank, metered to be 500ml
       Water tank, metered to be 1000ml + addition of Compound 200ml
       Water tank, metered to be 500ml + addition of Compound 20ml
       Compound metering pump 300ml/min, adjusted to supply 200 ml by a timer.
       Compound metering pump 20ml/min, adjusted to supply 20 ml by a timer.
     
    III. UTILITY REQUIREMENT
        1 Electrical Power:  220V x 1Ph (20A). 
        2 Tap water:  4L/Hr. (To be linked to the  right side of the  control unit by  8mm hose.)
     
    IV. INSTALLATION
     
                 Just place on the flat concrete floor without any anchoring.
    In case the equipment is not horizontally leveled, the mass in the tumbler can move to a side,
    please be careful.
     
                 Please link 3 wires from the motor to the U.V.W. terminal in the control box.
                 Please link 2 wires from the main source of electrical power to the R.T. terminal in the box.
           
                 Please link tap water to the supply valve on the right side of the control box by 8mm hose.
                 In case Tap water contains some foreign substance, please install pre-filter before this hose.
                 Please link a hose(20mm) from the hose nipple on left side of the control box to the main machine.
                 A little longer hose is shipped with machine, please cut it off and adjust depending on
    the site allocation
           
    .            Please link the discharge valve on the rear side of machine to the laboratory discharge pipe line.
                 Please leave the discharge valve always open except for the maintenance.
                 A compound container needs to be placed in the room under the control box.
                 Please remove the top lid and place the container in the room and put a separate lid pre-drilled
    on 3 places, 1 big hole in the center and 2 small holes on the right and left.
                 On the center hole, please place a level sensor which emit alarm when there is not enough
    compound in the container,
    and on the right and left holes insert 2 hoses that come from the metering pumps.
           
     
    V. OPERATION
     
       Supply the control box with power (put the Breaker switch ON, put the disconnect switch ON) and
    put the selector switch ON, then you will have light on the Power lamp.
     Fill the vibratory tumbler with media 15L (11.25L of Cone and 3.75L of Pyramid).
     
    Put the Mode to Manu and push on Start.
    If the mass turns from front to back, the motor direction is correct.
    In case it turns in the opposite direction please correct by changing the wire.
     
    1.     PREPARATION COURSE
    The media contains some flashes and burrs. This course is, prior to the main course of testing, 
    to condition the media by tumbling to the right purpose of the testing.
     
                      First of all, put MODE to Manu and push on PRE WATER-1, then 500ml tank will be filled with water.
                      Pls push on only once, if you push on twice it will be stopped.
    O                 Once it is full, it will be automatically disconnected. When the water is evacuated, the tank
     is automatically refilled, therefore from next time, there is no need to put to Manu and fill again.
    .
                 Set the timer 4 hours or 10 hours as required by your company (currently designated to be 10 hours).
                 Put Mode to PRE and push on Start then the tumbler will start to run and 2000 ml of water
    will be supplied automatically.(4 times of 500ml)
                      At the time of start, 2000ml will be supplied and 500ml will be supplied every 30 min. automatically.
     
      The tank always keeps water 500ml. and supplies when it is required.
     
    2. MAIN COURSE OF TESTING
       
    This course is to test whether the testing parts are safe or damaged when the media and parts
    have rubbed each other in the vibratory tumbler.
           
    First of all, put MODE to Manu and push on MAIN Water-1, then water will be ready with 1000ml
    in the tank 1, push on MAIN Water-2 then water will be ready with 500ml in the tank 2.
                      Push on Comp-1, then 200ml of compound will be added to 1000ml of water  in the tank-1.
                 Push on Comp-2, then 20ml of compound will be added to 500ml of water in the tank-2.
     
                  Pls push on only once, if you push on twice it will be stopped.
                  Once you have filled for the first time, when the liquid is evacuated, it is made again automatically
    therefore there is no need to do manually again.
                 Set the timer 1 hour or 2 hours as required by your company.
                 Put the MODE to Manu and start the machine, then 1000mml of water and 200ml of compound
    will be automatically supplied in the beginning and 500ml of water and 20ml of compound
    will be supplied every 30 min.
            
     (Note) When there is not enough compound, you will have Alarm light on the control panel,
    please fill the container with compound.
     
           VI. MAINTENANCE
     
                 In case the inverter inside the control box repeats to trip, one of the 3 wires from the motor
    might have been disconnected by the vibration. Please take out the vibratory tumbler from the
    sound proof box and disassemble the drain pipe lines and lift up the tub and check the wires
    from the motor. If any of the wires were disconnected, please correct it.
     
    In case there is any loud noise from the vibratory tumbler, the bearings on the motor must have
    broken, please replace them referring to the assembly drawing of the motor.
     
    In case the liquid of water and compound is not supplied well, some foreign substance might have
    been stuck in the ball, please clean the valve referring to the separate manual.
     
     In case compound is not well injected from the metering pump, please clean the balls on the
    suction and discharge port of the diaphragm pump.
    (Referring to the separate manual, pls clean part No. 2,3,4.)
    This may happen after long holidays.
     
    Please clean the filter that is installed right after the in-put water valve on the right side of
    the control box.
     
    VII. WARRANTY & FREE REPLACEMENT
       We warrant quality for either 380 days from the date of shipment or 2000 hours of operation,
    whichever comes first. In case any part does not work properly, we send replacement part only.
    韓國磨料
    韓國磨料
    .                 

    會員登錄

    ×

    請輸入賬號

    請輸入密碼

    =

    請輸驗證碼

    收藏該商鋪

    X
    該信息已收藏!
    標簽:
    保存成功

    (空格分隔,最多3個,單個標簽最多10個字符)

    常用:

    提示

    X
    您的留言已提交成功!我們將在第一時間回復您~
    在線留言
    主站蜘蛛池模板: 亚洲欧美成人一区二区在线电影| 成人性一级视频在线观看| 亚洲欧洲精品成人久久曰影片 | 国产成人青青热久免费精品| 成人免费视频69| 四虎成人国产精品视频| 国产免费69成人精品视频| 亚洲成人在线电影| 成成人看片在线| 亚洲欧美成人一区二区在线电影| 青青草成人在线| 国产成人一区二区三区视频免费 | 国产麻豆成人传媒免费观看| 久久久久99精品成人片试看| 成人午夜又粗又硬有大| 亚洲欧美综合乱码精品成人网| 色窝窝无码一区二区三区成人网站| 成人在线激情网| 欧美成人精品三级网站| 国产成人AV区一区二区三| 91成人免费观看在线观看| 国产成人精品高清免费| 日本在线高清视频日本在线观看成人小视频 | 69成人免费视频| 亚洲成人黄色网址| 免费在线成人网| 国产成人av在线影院| 国产成人精品午夜视频'| 成人美女黄网站视频大全| 777精品成人影院| 97色婷婷成人综合在线观看| 五月天国产成人AV免费观看| 国产成人无码AⅤ片在线观看| 欧美成人性动漫在线观看| 久久99国产精品成人欧美| www国产成人免费观看视频| 亚洲欧美成人综合久久久| 免费成人黄色大片| 久久久久久亚洲精品成人| 欧美成人全部费免网站| 欧美成人香蕉网在线观看|