    西門子CPU416

    參  考  價面議
    具體成交價以合同協議為準

    產品型號

    品       牌

    廠商性質代理商

    所  在  地上海市

    聯系方式:瞿曉明查看聯系方式

    更新時間:2016-05-09 16:32:16瀏覽次數:127次

    聯系我時,請告知來自 儀表網
    西門子CPU416,SIMATIC S7-400,CPU 416-2DP: 5.6MB(2.8MB代碼,2.8MB數據),位處理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP

    西門子CPU416,CPU416,西門子S7-400CPU416,西門子CPU416可編程控制器,*處理器,SIMATIC S7-400,CPU 416-2DP: 5.6MB(2.8MB代碼,2.8MB數據),位處理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP

    6ES7416-2XN05-0AB0

    SIMATIC S7-400,CPU 416-2DP: 5.6MB(2.8MB代碼,2.8MB數據),位處理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP

    6ES7416-2XP07-0AB0

    SIMATIC S7-400, CPU 416-2, CENTRAL PROCESSING UNIT WITH: 8 MB WORKING MEMORY, (4 MB CODE, 4 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP

    6ES7416-3ES07-0AB0

    SIMATIC S7-400, CPU 416-3 PN/DP CENTRAL PROCESSING UNIT WITH: 16 MB WORKING MEMORY, (8 MB KB CODE, 8 MB DATA), INTERFACES: 1. IF MPI/DP 12 MBIT/S (X1), 2. IF ETHERNET/PROFINET (X5), 3. IF IF964-DP PLUGABLE (IF1)

    6ES7416-3XR05-0AB0

    SIMATIC S7-400,CPU 416-3DP: 11.2MB(5.6MB代碼,5.6MB數據),位處理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP, 3. 可擴展的IF964-DP(IF1)接口

    6ES7416-3XS07-0AB0

    SIMATIC S7-400, CPU 416-3, CENTRAL PROCESSING UNIT WITH: 16 MB WORKING MEMORY, (8 MB KB CODE, 8 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP, 3. IF IFM MODULES PLUGGABLE

     

    德國* 現貨銷售 質保一年 歡迎詢價

    SIEMENS 上海翰粵自動化系統有限公司

    瞿曉明(銷售工程師)

    1324375156

     

      概述

    • 性能范圍內的高性能 CPU
    • 適用于對性能要求很高的工廠
    • CPU 416-3 PN/DP 中集成了 PROFINET 功能

     

    CPU 416-2, CPU 416-3 and CPU 416-3 PN/DP are powerful SIMATIC S7-400 CPUs.

    The integrated PROFIBUS DP interfaces in the CPU 416-2 and CPU 416-3 make it possible to connect directly to the PROFIBUS DP fieldbus as a master or slave.

    An additional DP master system can be connected to the CPU 416-3 and CPU 416-3 PN/DP using the IF 964-DP interface module.

    The integrated PROFINET interface of the CPU 416-3 PN/DP includes switch functionality when the ERTEC 400-ASIC is used. This forms the basis for providing two externally accessible PROFINET ports. In addition to hierarchical network topologies, this also enables the creation of line structures in the new S7-400 controllers.

    Note:
    Only the 6ES7 964-2AA04-0AB0 interface submodule may be used.

      設計

    Both CPUs are equipped with the following:

    • Powerful processor: 
      The CPUs achieve instruction execution times as low as 0.03 µs per binary instruction.
    • CPU 416-2: 5.6 MB RAM (of which 2.8 MB each for program and data); 
      CPU 416-3: 11.2 MB RAM (of which 5.6 MB each for program and data); 
      CPU 416-3 PN/DP: 11.2 MB RAM (of which 5.6 MB each for program and data); 
      fast RAM for parts of the user program relevant to execution.
    • Flexible expansion: 
      Up to 262144 digital and 16384 analog inputs/outputs.
    • Multi-point interface MPI: 
      With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPUs can establish up to 44 connections to stations of the communications bus (C bus) and the MPI.
    • Mode selector switch: 
      Designed as toggle switch.
    • Diagnostics buffer: 
      The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized.
    • Real-time clock: 
      The date and time are appended to diagnostic messages of the CPU.
    • Memory card: 
      For expansion of the integrated load memory. RAM and FEPROM cards (FEPROM for retentive storage) are available
    • Combined MPI/DP interface and integrated PROFIBUS DP interface (CPU 416-2 and CPU 416-3): 
      The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming). 
      Mixed configuration: SIMATIC S5 and SIMATIC S7 as PROFIBUS master according to EN 50170.

    CPU 416-3 and CPU 416-3 PN/DP also include:

    • A module slot: 
      An additional PROFIBUS DP master system can be connected via the IF 964-DP interface module.

    CPU 416-3 PN/DP additionally includes:

    • PROFINET interface with 2 ports (switch):
      • PROFINET I/O, 256 IO devices connectable
      • PROFINET CBA

      功能

    • Block protection: 
      A password concept protects the user program from unauthorized access.
    • Integral HMI services: 
      The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
    • Integrated communications functions:
      • PG/OP communication
      • Shared data communication
      • S7 standard communication
      • S7 communication
    • Firmware update using network

    CPU 416-3 PN/DP additional:

    • Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006)
    • Distributed inligence in Component Based Automation (CBA) on PROFINET
    • Additional diagnostic options with integrated web server

    Parameterizable attributes

    The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.

    • Multi-point interface MPI:
      • Definition of station addresses.
      • Startup/cycle behavior
      • Stipulation of the maximum cycle time and communications load
    • Address assignment: 
      Addressing of I/O modules.
    • Retentive ranges: 
      Definition of the number of retentive bit memories, counters, timers, data blocks and clock memories.
    • Size of the process image, local data.
    • Length of the diagnostics buffer
    • Protection level: 
      Definition of access authorization for program and data
    • System diagnostics: 
      Definition of the handling and scope of diagnostic messages
    • Timed interrupts: 
      Setting of periodicity

    CPU 416-3 PN/DP additional:

    • PROFINET interface
    • Parameterization of time synchronization using NTP procedure

    Indication and information functions

    • Status and error indicators: 
      LEDs indicate internal and external errors and operating states such as RUN, STOP, Restart, Test function, for example
    • Test functions: 
      The programming device can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components
    • Information functions: 
      The programming device can be used to provide the user with information on the memory capacity and operating mode of the CPU and the current utilization of the working and load memories

     

    Order number

    6ES7416-2XP07-0AB0

    6ES7416-3XS07-0AB0

    6ES7416-3ES07-0AB0

     

    CPU 416-2, MPI, PROFIBUS, 8 MB

    CPU 416-3, 16 MB, 3 INTERFACES

    CPU416-3 PN/DP, 16 MB, 3 INTERFACES

    General information

     

     

     

    Product type designation

    CPU 416-2

    CPU 416-3

    CPU416-3 PN/DP

    Engineering with

     

     

     

    • ● Programming package

    STEP 7 V5.4 or higher with HSP 261

    STEP 7 V5.4 or higher with HSP 261

    STEP 7 V5.5 or higher with HSP 262

    Supply voltage

     

     

     

    Rated value (DC)

     

     

     

    • ● 24 V DC

    No; Power supply via system power supply

    No; Power supply via system power supply

    No; Power supply via system power supply

    Power loss

     

     

     

    Power loss, typ.

    4.5 W

    5.5 W

    6.5 W

    Memory

     

     

     

    Work memory

     

     

     

    • ● integrated

    8 Mbyte

    16 Mbyte

    16 Mbyte

    • ● integrated (for program)

    4 Mbyte

    8 Mbyte

    8 Mbyte

    • ● integrated (for data)

    4 Mbyte

    8 Mbyte

    8 Mbyte

    Load memory

     

     

     

    • ● expandable FEPROM, max.

    64 Mbyte

    64 Mbyte

    64 Mbyte

    • ● integrated RAM, max.

    1 Mbyte

    1 Mbyte

    1 Mbyte

    • ● expandable RAM, max.

    64 Mbyte

    64 Mbyte

    64 Mbyte

    CPU processing times

     

     

     

    for bit operations, typ.

    12.5 ns

    12.5 ns

    12.5 ns

    for word operations, typ.

    12.5 ns

    12.5 ns

    12.5 ns

    for fixed point arithmetic, typ.

    12.5 ns

    12.5 ns

    12.5 ns

    for floating point arithmetic, typ.

    25 ns

    25 ns

    25 ns

    Counters, timers and their retentivity

     

     

     

    S7 counter

     

     

     

    • ● Number

    2 048

    2 048

    2 048

    IEC counter

     

     

     

    • ● present

    Yes

    Yes

    Yes

    S7 times

     

     

     

    • ● Number

    2 048

    2 048

    2 048

    IEC timer

     

     

     

    • ● present

    Yes

    Yes

    Yes

    Data areas and their retentivity

     

     

     

    Flag

     

     

     

    • ● Number, max.

    16 kbyte; Size of bit memory address area

    16 kbyte; Size of bit memory address area

    16 kbyte; Size of bit memory address area

    Address area

     

     

     

    I/O address area

     

     

     

    • ● Inputs

    16 kbyte

    16 kbyte

    16 kbyte

    • ● Outputs

    16 kbyte

    16 kbyte

    16 kbyte

    Process image

     

     

     

    • ● Inputs, adjustable

    16 kbyte

    16 kbyte

    16 kbyte

    • ● Outputs, adjustable

    16 kbyte

    16 kbyte

    16 kbyte

    Time of day

     

     

     

    Clock

     

     

     

    • ● Hardware clock (real-time clock)

    Yes

    Yes

    Yes

    Operating hours counter

     

     

     

    • ● Number

    16

    16

    16

    Interfaces

     

     

     

    Interfaces/bus type

    1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP

    1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 1 x PROFIBUS DP (optionally pluggable)

    1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports), 1 x PROFIBUS DP (optionally pluggable)

    Number of RS 485 interfaces

    2; Combined MPI / PROFIBUS DP and PROFIBUS DP

    2; Combined MPI / PROFIBUS DP and PROFIBUS DP

    1; Combined MPI / PROFIBUS DP

    Number of other interfaces

     

    1; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0)

    1; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0)

    1. Interface

     

     

     

    Interface type

    Integrated

    Integrated

    Integrated

    Physics

    RS 485 / PROFIBUS + MPI

    RS 485 / PROFIBUS + MPI

    RS 485 / PROFIBUS + MPI

    Functionality

     

     

     

    • ● MPI

    Yes

    Yes

    Yes

    • ● DP master

    Yes

    Yes

    Yes

    • ● DP slave

    Yes

    Yes

    Yes

    DP master

     

     

     

    • ● Number of DP slaves, max.

    32

    32

    32

    2. Interface

     

     

     

    Interface type

    Integrated

    Integrated

    PROFINET

    Physics

    RS 485 / PROFIBUS

    RS 485 / PROFIBUS

    Ethernet RJ45

    Interface types

     

     

     

    • ● Number of ports

     

     

    2

    Functionality

     

     

     

    • ● DP master

    Yes

    Yes

    No

    • ● DP slave

    Yes

    Yes

    No

    • ● PROFINET IO Controller

     

     

    Yes

    • ● PROFINET IO Device

     

     

    Yes

    • ● PROFINET CBA

     

     

    Yes

    DP master

     

     

     

    • ● Number of DP slaves, max.

    125

    125

     

    3. Interface

     

     

     

    Interface type

     

    Pluggable interface module (IF), technical data as for 2nd interface

    Pluggable interface module (IF)

    Plug-in interface modules

     

    IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

    IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

    Physics

     

    RS 485 / PROFIBUS

    RS 485 / PROFIBUS

    Functionality

     

     

     

    • ● MPI

     

    No

    No

    • ● DP master

     

    Yes

    Yes

    • ● DP slave

     

    Yes

    Yes

    DP master

     

     

     

    • ● Number of DP slaves, max.

     

    125

    125

    Isochronous mode

     

     

     

    Isochronous operation (application synchronized up to terminal)

    Yes; For PROFIBUS only

    Yes; For PROFIBUS only

    Yes; Via PROFIBUS DP or PROFINET interface

    Communication functions

     

     

     

    PG/OP communication

    Yes

    Yes

    Yes

    Data record routing

    Yes

    Yes

    Yes

    Global data communication

     

     

     

    • ● supported

    Yes

    Yes

    Yes

    S7 basic communication

     

     

     

    • ● supported

    Yes

    Yes

    Yes

    S7 communication

     

     

     

    • ● supported

    Yes

    Yes

    Yes

    S5 compatible communication

     

     

     

    • ● supported

    Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

    Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

    Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

    Standard communication (FMS)

     

     

     

    • ● supported

    Yes; Via CP and loadable FB

    Yes; Via CP and loadable FB

    Yes; Via CP and loadable FB

    Open IE communication

     

     

     

    • ● TCP/IP

     

     

    Yes; via integrated PROFINET interface and loadable FBs

    • — Number of connections, max.

     

     

    94

    • ● ISO-on-TCP (RFC1006)

    Via CP 443-1 and loadable FB

    Via CP 443-1 and loadable FB

    Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs

    • — Number of connections, max.

     

     

    94

    • ● UDP

     

     

    Yes; via integrated PROFINET interface and loadable FBs

    • — Number of connections, max.

     

     

    94

    Web server

     

     

     

    • ● supported

    No

    No

    Yes

    Number of connections

     

     

     

    • ● overall

    96

    96

    96

    Standards, approvals, certificates

     

     

     

    Use in hazardous areas

     

     

     

    • ● ATEX

    ATEX II 3 G Ex nA IIC T4 Gc

    ATEX II 3 G Ex nA IIC T4 Gc

    ATEX II 3 G Ex nA IIC T4 Gc

    Ambient conditions

     

     

     

    Ambient temperature during operation

     

     

     

    • ● min.

    0 °C

    0 °C

    0 °C

    • ● max.

    60 °C

    60 °C

    60 °C

    Configuration

     

     

     

    Know-how protection

     

     

     

    • ● User program protection/password protection

    Yes

    Yes

    Yes

    • ● Block encryption

    Yes; With S7 block Privacy

    Yes; With S7 block Privacy

    Yes; With S7 block Privacy

    Dimensions

     

     

     

    Width

    25 mm

    50 mm

    50 mm

    Height

    290 mm

    290 mm

    290 mm

    Depth

    219 mm

    219 mm

    219 mm

    Weights

     

     

     

    Weight, approx.

    700 g

    900 g

    900 g

     

    會員登錄

    ×

    請輸入賬號

    請輸入密碼

    =

    請輸驗證碼

    收藏該商鋪

    X
    該信息已收藏!
    標簽:
    保存成功

    (空格分隔,最多3個,單個標簽最多10個字符)

    常用:

    提示

    X
    您的留言已提交成功!我們將在第一時間回復您~
    在線留言
    主站蜘蛛池模板: 国产成人精品久久综合| 成人a免费α片在线视频网站| 亚洲成人免费网站| 午夜精品成人毛片| 69国产成人精品视频软件| 欧洲成人r片在线观看| 成人精品一区二区久久| 国产成人无码综合亚洲日韩| 亚洲av成人一区二区三区| 成人超污免费网站在线看| 国产精品成人网| 2021国产成人精品国产| 国产成人精品久久亚洲高清不卡| 久久亚洲AV成人无码国产| 成人无码精品一区二区三区| 国产成人av免费观看| 日韩国产成人精品视频| 亚洲高清成人欧美动作片| 成人三级精品视频在线观看| 91成人精品视频| 免费网站看v片在线成人国产系列 免费观看一级成人毛片 | 国产成人AV一区二区三区无码| 色老头成人免费视频天天综合 | 国产成人麻豆亚洲综合无码精品| 亚洲AV成人噜噜无码网站| 国产成人免费永久播放视频平台| 成人区人妻精品一区二区不卡| 综合558欧美成人永久网站| 免费视频成人片在线观看| 四虎成人永久地址| 国产成人免费ā片在线观看老同学 | 国产成人亚洲综合无| 红楼遗梦成人h文完整版| 亚洲av成人综合网| 亚洲国产成人精品激情| 亚洲无成人网77777| 亚洲国产精品无码成人片久久 | 18成人片黄网站www| 久久久久99精品成人片| www亚洲欲色成人久久精品| 老司机成人影院|