    科孚勒(Correflow)顆粒物監測儀 MFM 5100/ MFM 5200/ MFM 5600

    詳細介紹

    科孚勒(Correflow)顆粒物監測儀 MFM 5100/ MFM 5200/ MFM 5600


    MFM 5100

    Particulate Matter Mass Flow Monitor with High Sensitivity

    Sensing the electrical field changes induced by the particles motion in gas flow, MFM 5100 can measure the particle flow rate or concentration based on electrical field and flow dynamics models. Extracting particle flow information from electrostatic flow noises with digital signal processing algorithms, MFM 5100 can achieve stable and reliable results with extremely high sensitivity.

    Benefits
    • Preventive monitoring to reduce equipment maintenance cost

    • Management equipment performance in real time, locate problem with no delay

    Application
    • Particulate matter flow monitoring in low concentration condition, such as after dust collector, for preventive monitoring

    Specifications
    • Precision: up to 0.01mg/m3

    • Range: 0~500mg/m3

    • Zero drift:<0.01%FS

    • Repetitive Error: < 2%

    • Automatic probe contamination check

    • Flow media velocity range: 5~35m/s



    MFM 6100

    Two-Phase Mass Flow Meter

    The Correflow MFM combines the technology of two patented measurement techniques (velocity and concentration) in a single sensor to achieve a measurement of mass flow. The first measurement determines the two phase slurry velocity and the second measurement determines the fraction of one of the phases of the mixture in relation to the other. Combining these two parameters yields mass per unit time (ie. mass flow).

    • Two Component Concentrations: 1% to 99%

    • Materials: Insulating liquids, solids (particulate), gas (bubbles or as carrier)

    • Typical Response Time: Concentration–updated at 2.5 millisecond intervals using last measured velocity; Velocity–typically updated once per second

    • Purge Option: Type Z purged (NEMA 4X): Cl1, Div 2, GR C&D

    • European (Eex approved) housing also available

    • Sensor: Typical Sensor Pipe sizes: 1/8" (.32 cm) ID or greater

    • Pressure limits: 1000 psi (69 bar) typical for small sensors, Higher pressure designs available. No moving parts, no flow restrictions or additional pressure drop

    • Power Requirements: 115 to 240 VAC, 50 to 60 Hz (100 Watts maximum)

    • Instrument air for optional pressurization(intermittently 4 scfm @ 80 to 120 psi)

    • Data Analysis Velocity, volume fraction, mass fraction, mass flow measurements on an instantaneous basis and averaged over user programmed time intervals, Total mass for fixed time intervals, Stream temperature

    • Calibration Routines: Sensor self-tuning with optional dynamic auto-zeroing routines; Adjustable gain on concentration and velocity measurement circuitry; Adjustable signal filtering on concentration measurement circuitry; Adjustable sampling rate for a wide range of process conditions

    • Software and fully installed PC available

    • Sensor connections designed intrinsically safe

    • Each sensor has Four 4-20mA outputs which are independently

    • programmable to any Four of 12 available parameters

    • MODBUS over RS485 or Ethernet communications: communication or data read out for remote parameter adjustment, calibration and testing.

    • Various digital and analog inputs optionally available

    Benefits
    • Continuous analysis with selectable time averaging

    • No moving parts, unaffected by vibration

    • No additional pressure drop

    • Selectable output scaling

    • Designed intrinsically safe

    • Ruggedized for the factory environment

    • Instantaneous and average mass flow outputs

    • Non-contact measurement

    Application
    • Maintaining maximum reactor productivity is only one of the concerns addressed by the modem-equipped Correflow unit. The rate at which catalyst is delivered to a reaction is also critical in achieving desired mechanical properties. The MFM System also provides early warning for abnormal operation such as clogged feed lines and empty feed pots. Due to the residence time of the catalyst, controllers without the MFM would not have real-time feedback and would have to wait until the reaction slowed before realizing that there was a problem. The MFM6100 enables closed-loop process control to automatically monitor and adjust catalyst flow for maximum reactor efficiency.

     


    MFM 5100

    Particulate Matter Mass Flow Monitor with High Sensitivity

    Sensing the electrical field changes induced by the particles motion in gas flow, MFM 5100 can measure the particle flow rate or concentration based on electrical field and flow dynamics models. Extracting particle flow information from electrostatic flow noises with digital signal processing algorithms, MFM 5100 can achieve stable and reliable results with extremely high sensitivity.

    Benefits
    • Preventive monitoring to reduce equipment maintenance cost

    • Management equipment performance in real time, locate problem with no delay

    Application
    • Particulate matter flow monitoring in low concentration condition, such as after dust collector, for preventive monitoring

    Specifications
    • Precision: up to 0.01mg/m3

    • Range: 0~500mg/m3

    • Zero drift:<0.01%FS

    • Repetitive Error: < 2%

    • Automatic probe contamination check

    • Flow media velocity range: 5~35m/s

     

    MFM 5200

    Particulate Matter Mass Flow Monitor with High Noise Resistance

    Sensing the electrical field changes induced by the particles motion in gas flow, MFM 5200 can measure the particle flow rate or concentration based on electrical field and flow dynamics models. Extracting particle flow information from electrostatic flow noises with digital signal processing algorithms, MFM 5200 can achieve stable and reliable results without affected by strong interference, such as ion stream or electric field changes.

    Benefits
    • Preventive monitoring to reduce equipment maintenance cost

    • Management equipment performance in real time, locate problem with no delay

    Application
    • Particulate matter flow monitoring in low concentration condition but with possible strong interference, such as after ESP, for efficiency monitoring

    Specifications
    • Precision: up to 0.01mg/m3

    • Range: 0~1000mg/m3

    • Zero drift:<0.01%FS

    • Repetitive Error: < 2%

    • Automatic probe contamination check

    • Flow media velocity range: 5~35m/s




    MFM 5600

    Particulate Matter Mass Flow Monitor with High Dynamic Range

    Sensing the electrical field changes induced by the particles motion in gas flow, MFM 5600 can measure the particle flow rate or concentration based on electrical field and flow dynamics models. Extracting particle flow information from electrostatic flow noises with digital signal processing algorithms, MFM 5600 can achieve stable and reliable results under high particle concentration flow condition.

    Benefits

    §  Monitor equipment load, reduce equipment maintenance cost

    §  Measure flow rate under heavy flow conditions, such as pneumatic transport, for stable process operation

    §  Prevent blockage

    Application

    §  Particulate matter flow monitoring in high concentration condition, such pneumatic transport, for stable process operation

    Specifications

    §  Precision: 1mg/m3

    §  Range: 0~100g/m3

    §  Zero drift:<0.01%FS

    §  Repetitive Error: < 2%

    §  Automatic probe contamination check

    §  Flow media velocity range: 5~35m/s


    MFM 7600

    Particulate Matter Mass Flow Monitor under Condensation Condition

    Sensing the electrical field changes induced by the particles motion in gas flow, MFM 7600 can measure the particle flow rate or concentration based on electrical field and flow dynamics models. Extracting particle flow information from electrostatic flow noises with digital signal processing algorithms, MFM 7600 can achieve stable and reliable results even under possible condensation condition.

    Benefits
    • Monitor particle flow rate or concentration in stack or on de-sulfur process outlet load, reduce equipment maintenance cost

    • Management equipment performance and optimize efficiency in real time

    Application
    • Particulate matter flow monitoring in possible condensation condition

    Specifications
    • Precision: up to 0.01mg/m3

    • Range: 0~100mg/m3

    • Zero drift:<0.01%FS

    • Repetitive Error:< 2%

    • Automatic probe contamination check

    • Flow media velocity range: 5~35m/s


    關鍵詞:顆粒物監測儀
    其他推薦產品更多>>

    感興趣的產品PRODUCTS YOU ARE INTERESTED IN

    儀表網 設計制作,未經允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.caria-chile.com,All rights reserved.

    以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,儀表網對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

    會員登錄

    ×

    請輸入賬號

    請輸入密碼

    =

    請輸驗證碼

    收藏該商鋪

    登錄 后再收藏

    提示

    您的留言已提交成功!我們將在第一時間回復您~
    主站蜘蛛池模板: 国产成人无码区免费内射一片色欲 | 欧美成人性色区| 亚洲2022国产成人精品无码区| 亚洲国产成人无码av在线影院| 亚洲国产成人久久综合一区| 欧美在线成人午夜网站| 国产成人精品A视频一区| 亚洲精品成人区在线观看| 成人免费视频网站| 亚洲国产aⅴ成人精品无吗| 女性成人毛片a级| 欧美综合成人网| 亚洲国产成人超福利久久精品| 成人看片黄a在线观看| 亚洲国产成人99精品激情在线| 影院成人区精品一区二区婷婷丽春院影视 | 国产精品成人免费福利| 2021成人国产精品| 国产成人精品午夜福利| 日本成人免费在线视频| 中国国产成人精品久久| 亚洲精品国产成人| 国产成人精品视频一区| 成人欧美一区二区三区黑人| 久久久成人影院| 1000部国产成人免费视频| 亚洲国产成人超福利久久精品| 国产成人久久777777| 国产成人a大片大片在线播放| 成人免费网站在线观看| 欧洲成人在线视频| 欧美成人全部视频| 欧美成人精品高清在线观看| www夜片内射视频日韩精品成人| 亚洲国产成人va在线观看| 一级毛片成人午夜| 成人福利app| 国产成人精品无码一区二区老年人 | 国产成人免费a在线视频色戒| 在线观看国产成人AV片| 国产成人亚洲精品无码青青草原|